Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 288
Filtrar
1.
BMC Oral Health ; 24(1): 429, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38584280

RESUMO

BACKGROUND: Accurate assessment of remaining dentin thickness (RDT) is paramount for restorative decisions and treatment planning of vital teeth to avoid any pulpal injury. This diagnostic accuracy study compared the validity and patient satisfaction of an electrical impedance based device Prepometer™ (Hager & Werken, Duisburg, Germany) versus intraoral digital radiography for the estimation of remaining dentin thickness in carious posterior permanent teeth. METHODS: Seventy patients aged 12-25 years with carious occlusal or proximal permanent vital posterior teeth were recruited. Tooth preparation was performed to receive an adhesive restoration. Pre- and post-excavation RDT were measured radiographically by two calibrated raters using the paralleling periapical technique. Prepometer™ measurements were performed by the operator. Patients rated their satisfaction level with each tool on a 4-point Likert scale and 100 mm visual analog scale (VAS). Inter and intragroup comparisons were analyzed using signed rank test, while agreement between devices and observations was tested using weight kappa (WK) coefficient. RESULTS: the intergroup comparisons showed that, before and after excavation, there was a significant difference between measurements made by both techniques (p < 0.001). After excavation, there was a weak agreement between measurements (WK = 0.2, p < 0.001), whereas before excavation, the agreement was not statistically significant (p = 0.407). Patients were significantly more satisfied with Prepometer™ based on scales and VAS (p < 0.001). CONCLUSION: Prepometer™ could be a viable clinical tool for determining RDT with high patient satisfaction, while radiographs tended to overestimate RDT in relation to the Prepometer™.


Assuntos
Cárie Dentária , Satisfação do Paciente , Humanos , Impedância Elétrica , Intensificação de Imagem Radiográfica , Dentina/diagnóstico por imagem , Cárie Dentária/diagnóstico por imagem , Cárie Dentária/terapia
2.
Ann Dermatol ; 36(2): 99-111, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38576248

RESUMO

BACKGROUND: Skin barrier function assessment is commonly done by measuring transepidermal water loss (TEWL). An important limitation of this method is the influence of intrinsic and extrinsic factors. Electrical impedance spectroscopy (EIS) is a lesser-established method for skin barrier function assessment. Some influential factors have been described, but no guidelines exist regarding the standardization of these measurements. OBJECTIVE: To evaluate the effect size of daily routine activities on TEWL and EIS, as well as their correlation with age and anatomical differences. METHODS: Healthy participants (n=31) were stratified into three age groups (18-29, 30-49, and ≥50 years). In a climate-controlled room, EIS and TEWL measurements were performed on the left and right volar forearm and abdomen. RESULTS: Body cream application decreased TEWL and EIS values after 15 and 90 minutes. Skin washing decreased TEWL for 15 minutes and EIS values for at least 90 minutes. TEWL was increased 5 minutes after moderate to intense exercise. Coffee intake increased TEWL on the abdomen after 60 minutes. TEWL and EIS values did not correlate with participants' age and no anatomical differences were observed. No correlation was observed between TEWL and EIS. CONCLUSION: Body cream application and skin washing should be avoided at least 90 minutes prior to measurements of TEWL and EIS. Exercise and coffee intake should also be avoided prior to TEWL measurements. EIS may be a promising tool for skin barrier function assessment as it is less affected by daily routine activities than TEWL.

3.
J Clin Med ; 13(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38592144

RESUMO

Surface electromyography (sEMG) is a technique for measuring and analyzing the electrical signals of muscle activity using electrodes placed on the skin's surface. The aim of this paper was to outline the history of the development and use of surface electromyography in dentistry, to show where research and technical solutions relating to surface electromyography currently lie, and to make recommendations for further research. sEMG is a diagnostic technique that has found significant application in dentistry. The historical section discusses the evolution of sEMG methods and equipment, highlighting how technological advances have influenced the accuracy and applicability of this method in dentistry. The need for standardization of musculoskeletal testing methodology is highlighted and the needed increased technical capabilities of sEMG equipment and the ability to specify parameters (e.g., sampling rates, bandwidth). A higher sampling rate (the recommended may be 2000 Hz or higher in masticatory muscles) allows more accurate recording of changes in the signal, which is essential for accurate analysis of muscle function. Bandwidth is one of the key parameters in sEMG research. Bandwidth determines the range of frequencies effectively recorded by the sEMG system (the recommended frequency limits are usually between 20 Hz and 500 Hz in masticatory muscles). In addition, the increased technical capabilities of sEMG equipment and the ability to specify electromyographic parameters demonstrate the need for a detailed description of selected parameters in the methodological section. This is necessary to maintain the reproducibility of sEMG testing. More high-quality clinical trials are needed in the future.

4.
J Pers Med ; 14(3)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38541000

RESUMO

Post-stroke complex regional pain syndrome (CRPS) poses challenges in pain assessment for survivors. Stellate ganglion block (SGB) is a treatment, but evaluating its effectiveness is difficult for patients with communication limitations. Edema, a prominent symptom, can serve as an evaluation marker. Bioelectrical impedance analysis (BIA), assessing body composition and fluid status, is used independently of patient cooperation. This retrospective, observational pilot study aims to explore BIA's utility as an assessment tool post-SGB, revealing the effects and time courses of a single SGB on the bodily composition of post-stroke CRPS patients. Seven patients received ultrasound-guided SGB with a 5 mL solution containing 4 mL of 0.25% bupivacaine hydrochloride and 40 mg of triamcinolone into the prevertebral muscle space. BIA compared measures between affected and unaffected arms. The affected arm had higher segmental body water (SBW) and extracellular water ratios before SGB (p = 0.028 and p = 0.018, respectively). The SBW of the affected side, the SBW ratio, and the 1 and 5 kHz SFBIA ratios improved over time (p = 0.025, 0.008, 0.001, and 0.005, respectively). Rapid improvement occurred around 3 days post-injection, with maximum effects within approximately 1 week, persisting up to 3 weeks. SGB successfully reduced edema in post-stroke CRPS patients, with BIA serving as a useful tool for follow-up, facilitating the development of efficient treatment plans.

5.
Clin Exp Reprod Med ; 51(1): 48-56, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38433014

RESUMO

OBJECTIVE: This study investigated the relationship of anthropometric and metabolic risk factors with seminal and sex steroidal hormone parameters in a screened population of healthy males. METHODS: The participants were healthy young men without chronic or congenital diseases. The body composition parameters that we investigated were measured weight, height, and waist circumference (WC), as well as bioelectrical impedance analysis. Semen samples were analyzed for semen volume, sperm concentration, sperm motility and morphology, seminal pH, and liquefaction time. Biochemistry analysis, including glucose and lipid metabolism parameters, was conducted on fasting blood samples. Testicular volume was calculated separately for each testis using ultrasonography. RESULTS: Body mass index exhibited an inverse association with total sperm count. WC showed negative correlations with numerous seminal parameters, including sperm concentration, total sperm count, sperm morphology, and follicle-stimulating hormone levels. The basal metabolic rate was associated with seminal pH, liquefaction time, and sperm motility. WC, fat mass percentage, and triglyceride levels exhibited negative correlations with sex hormone binding globulin. The measures of glucose metabolism were associated with a greater number of seminal parameters than the measures of cholesterol metabolism. C-reactive protein levels were inversely associated with sperm concentration and total sperm count. CONCLUSION: Anthropometric and metabolic risk factors were found to predict semen quality and alterations in sex steroidal hormone levels.

6.
Breastfeed Med ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38469624

RESUMO

Background: Obesity is characterized as a low-grade chronic inflammatory state, marked by elevated inflammatory biomarkers. Breast milk (BM) is rich in nutritional elements, vitamins, minerals, immunological factors, and bioactive components. These bioactive components, capable of influencing biological processes, may vary in concentration based on maternal body composition. Research Aim/Question(s): This study aimed to explore the association between pro-inflammatory cytokine levels (interleukin-1 beta [IL-1ß], interleukin-6 [IL-6], and tumor necrosis factor-alpha [TNF-α]) in human colostrum and maternal body composition, as analyzed through bioelectrical impedance vector analysis (BIVA). Method: In this cross-sectional study, 117 healthy postpartum participants were included, with each group (normal weight, overweight, and obese) comprising 39 individuals, as classified by BIVA. Colostrum samples were collected within the first 24 hours postpartum. Results: IL-1ß levels did not significantly differ across the groups, with concentrations of 69.5 ± 103 pg/mL in normal-weight, 79.7 ± 97.9 pg/mL in overweight, and 68.7 ± 108 pg/mL in obese women. IL-6 levels were significantly higher in the overweight group (55 ± 72.4 pg/mL) than in the normal-weight (48.1 ± 74.1 pg/mL) and obese groups (28.9 ± 36.2 pg/mL) (p = 0.02). Similarly, TNF-α levels were higher in the overweight group, with concentrations of 58.7 ± 74.9 pg/mL, than in the normal-weight group, with concentrations of 38.6 ± 95.4 pg/mL, and 52.6 ± 115 pg/mL in obese women (p = 0.02). Conclusion: This study shows that IL-6 and TNF-α concentrations were statistically higher in the colostrum of overweight women, suggesting that maternal body composition may influence the inflammatory profile of BM.

7.
J Clin Med ; 13(3)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38337547

RESUMO

Background: Prone position (PP) and the positive end-expiratory pressure (PEEP)-induced lung recruitment maneuver (LRM) are both efficient in improving oxygenation and prognosis in patients with ARDS. The synergistic effect of PP combined with PEEP-induced LRM in patients with ARDS remains unclear. We aim to explore the effects of PP combined with PEEP-induced LRM on prognosis in patients with moderate to severe ARDS and the predicting role of lung recruitablity. Methods: Patients with moderate to severe ARDS were consecutively enrolled. The patients were prospectively assigned to either the intervention (PP with PEEP-induced LRM) or control groups (PP). The clinical outcomes, respiratory mechanics, and electric impedance tomography (EIT) monitoring results for the two groups were compared. Lung recruitablity (recruitment-to-inflation ratio: R/I) was measured during the PEEP-induced LRM procedure and was used for predicting the response to LRM. Results: Fifty-eight patients were included in the final analysis, among which 28 patients (48.2%) received PEEP-induced LRM combined with PP. PEEP-induced LRM enhanced the effect of PP by a significant improvement in oxygenation (∆PaO2/FiO2 75.8 mmHg vs. 4.75 mmHg, p < 0.001) and the compliance of respiratory system (∆Crs, 2 mL/cmH2O vs. -1 mL/cmH2O, p = 0.02) among ARDS patients. Based on the EIT measurement, PP combined with PEEP-induced LRM increased the ventilation distribution mainly in the dorsal region (5.0% vs. 2.0%, p = 0.015). The R/I ratio was measured in 28 subjects. The higher R/I ratio was related to greater oxygenation improvement after LRM (Pearson's r = 0.4; p = 0.034). Conclusions: In patients with moderate to severe ARDS, PEEP-induced LRM combined with PP can improve oxygenation and dorsal ventilation distribution. R/I can be useful to predict responses to LRM.

8.
Int J Heart Fail ; 6(1): 22-27, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38303915

RESUMO

Body fluid monitoring and management are essential to control dyspnea and prevent re-hospitalization in patients with chronic heart failure (HF). There are several methods to estimate and monitor patient's volume status, such as symptoms, signs, body weight, and implantable devices. However, these methods might be difficult to use for reasons that are slow to reflect body water change, inaccurate in specific patients' condition, or invasive. Bioelectrical impedance analysis (BIA) is a novel method for body water monitoring in patients with HF, and the value in prognosis has been proven in previous studies. We aim to determine the efficacy and safety of home BIA body water monitoring-guided HF treatment in patients with chronic HF. This multi-center, open-label, randomized control trial will enroll patients with HF who are taking loop diuretics. The home BIA group patients will be monitored for body water using a home BIA device and receive messages regarding their edema status and direction of additional diuretics usage or behavioral changes through the linked application system once weekly. The control group patients will receive the usual HF management. The primary endpoint is the change in N-terminal prohormone of brain natriuretic peptide levels from baseline after 12 weeks. This trial will provide crucial evidence for patient management with a novel home BIA body water monitoring system in patients with HF.

9.
J Phys Ther Sci ; 36(2): 63-68, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38304153

RESUMO

[Purpose] This study aimed to evaluate the relationship between lower extremity phase angle and muscle thickness/echo intensity in males with chronic spinal cord injury. It also compared bioelectrical impedance analysis measurements to investigate skeletal muscle degeneration between individuals with spinal cord injury and healthy controls. [Participants and Methods] This cross-sectional study included 12 male patients with chronic spinal cord injury and 14 healthy male controls. We used bioelectrical impedance analysis and ultrasonography to measure the lower extremity phase angle and muscle thickness/echo intensity of the rectus femoris muscle, respectively. We also compared the bioelectrical impedance analysis measurements between individuals with spinal cord injury and healthy controls. [Results] Lower extremity phase angle was strongly correlated with muscle thickness and echo intensity of the rectus femoris muscle in individuals with spinal cord injury. All measures differed significantly between individuals with spinal cord injury and healthy controls. [Conclusion] These findings suggest that lower extremity phase angle is a valuable skeletal muscle indicator in spinal cord injury. Furthermore, bioelectrical impedance analysis revealed degeneration of the lower extremity skeletal muscles in individuals with chronic spinal cord injury.

10.
BMC Sports Sci Med Rehabil ; 16(1): 34, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308310

RESUMO

BACKGROUND: Phase angle (PhA) is a prognostic marker of all-cause mortality in chronic kidney disease. However, no study has investigated this marker as a predictor of exercise intolerance in hemodialysis (HD) patients. The aim of this study was to determine a cut-off point for the PhA capable of discriminating HD patients with reduced exercise tolerance. METHODS: Thirty-one patients (80.6% men, median age 69 years) were included. The evaluations were performed on three different days, before the HD session. The outcomes evaluated were: biochemical markers, inflammatory and nutritional status, body composition, peripheral muscle strength and exercise tolerance. Performance ≤50% of the predicted value in the six-minute step test (6MST) was defined as reduced exercise tolerance. RESULTS: Patients presented an average of 67.6 steps (50.5% of predicted) in the 6MST. Fifteen patients (48.4%) were classified with reduced exercise tolerance. The receiver operating characteristic curve indicated a cut-off point of 3.73° for the PhA (sensitivity = 87%, specificity = 81%, and area under the curve = 0.88 [95% CI: 0.76-1.00]; p < 0.001). Patients with reduced exercise tolerance had worse inflammatory and nutritional status, lower PhA and greater impairment of peripheral muscle strength. CONCLUSION: The cut-off point of 3.73° for the PhA is sensitive and specific to discriminate HD patients with reduced exercise tolerance. TRIAL REGISTRATION: This study was registered in the Clinical Trials database (no. NCT03779126, date of first registration 19/12/2018).

11.
Korean J Anesthesiol ; 77(1): 115-121, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37211764

RESUMO

BACKGROUND: Alveoli tend to collapse in patients with acute respiratory distress syndrome (ARDS). Endotracheal aspiration may increase alveolar collapse due to the loss of end-expiratory lung volume (EELV). We aimed to compare the loss of EELV after open and closed suction in patients with ARDS. METHODS: This randomized crossover study included 20 patients receiving invasive mechanical ventilation for ARDS. Open and closed suction were applied in a random order. Lung impedance was measured using electric impedance tomography. The change in end-expiratory lung impedance end of suction and at 1, 10, 20, and 30 min after suction, was used to represent the change in EELV. Arterial blood gas analyses and ventilatory parameters such as the plateau pressure (Pplat), driving pressure (Pdrive), and compliance of the respiratory system (CRS) were also recorded. RESULTS: Less volume loss was noted after closed suction than after open suction (mean ΔEELI: -2661 ± 1937 vs. -4415 ± 2363; mean difference: -1753; 95% CI [-2662, -844]; P = 0.001). EELI returned to baseline 10 min after closed suction but did not return to baseline even 30 min after open suction. After closed suction, the Pplat and Pdrive decreased while the CRS increased. Conversely, the Pplat and Pdrive increased while the CRS decreased after open suction. CONCLUSIONS: Endotracheal aspiration may result in alveolar collapse due to loss of EELV. Given that closed suction is associated with less volume loss at end-expiration without worsening ventilatory parameters, it should be chosen over open suction in patients with ARDS.


Assuntos
Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório , Humanos , Respiração com Pressão Positiva/métodos , Estudos Cross-Over , Medidas de Volume Pulmonar , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/terapia
12.
Skelet Muscle ; 13(1): 19, 2023 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-37980539

RESUMO

BACKGROUND: The lack of functional dystrophin protein in Duchenne muscular dystrophy (DMD) causes chronic skeletal muscle inflammation and degeneration. Therefore, the restoration of functional dystrophin levels is a fundamental approach for DMD therapy. Electrical impedance myography (EIM) is an emerging tool that provides noninvasive monitoring of muscle conditions and has been suggested as a treatment response biomarker in diverse indications. Although magnetic resonance imaging (MRI) of skeletal muscles has become a standard measurement in clinical trials for DMD, EIM offers distinct advantages, such as portability, user-friendliness, and reduced cost, allowing for remote monitoring of disease progression or response to therapy. To investigate the potential of EIM as a biomarker for DMD, we compared longitudinal EIM data with MRI/histopathological data from an X-linked muscular dystrophy (mdx) mouse model of DMD. In addition, we investigated whether EIM could detect dystrophin-related changes in muscles using antisense-mediated exon skipping in mdx mice. METHODS: The MRI data for muscle T2, the magnetic resonance spectroscopy (MRS) data for fat fraction, and three EIM parameters with histopathology were longitudinally obtained from the hindlimb muscles of wild-type (WT) and mdx mice. In the EIM study, a cell-penetrating peptide (Pip9b2) conjugated antisense phosphorodiamidate morpholino oligomer (PPMO), designed to induce exon-skipping and restore functional dystrophin production, was administered intravenously to mdx mice. RESULTS: MRI imaging in mdx mice showed higher T2 intensity at 6 weeks of age in hindlimb muscles compared to WT mice, which decreased at ≥ 9 weeks of age. In contrast, EIM reactance began to decline at 12 weeks of age, with peak reduction at 18 weeks of age in mdx mice. This decline was associated with myofiber atrophy and connective tissue infiltration in the skeletal muscles. Repeated dosing of PPMO (10 mg/kg, 4 times every 2 weeks) in mdx mice led to an increase in muscular dystrophin protein and reversed the decrease in EIM reactance. CONCLUSIONS: These findings suggest that muscle T2 MRI is sensitive to the early inflammatory response associated with dystrophin deficiency, whereas EIM provides a valuable biomarker for the noninvasive monitoring of subsequent changes in skeletal muscle composition. Furthermore, EIM reactance has the potential to monitor dystrophin-deficient muscle abnormalities and their recovery in response to antisense-mediated exon skipping.


Assuntos
Distrofina , Distrofia Muscular de Duchenne , Camundongos , Animais , Distrofina/genética , Distrofina/metabolismo , Camundongos Endogâmicos mdx , Impedância Elétrica , Camundongos Endogâmicos C57BL , Distrofia Muscular de Duchenne/diagnóstico por imagem , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/patologia , Músculo Esquelético/metabolismo , Morfolinos/farmacologia , Morfolinos/uso terapêutico , Miografia , Biomarcadores
13.
Physiol Meas ; 44(12)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38029441

RESUMO

Objective. This study aimed to investigate the capacity of the bioelectrical muscle localized phase angle (ML-PhA) as an indicator of muscle power and strength compared to whole body PhA (WB-PhA).Approach. This study assessed 30 young women (22.1 ± 3.2 years) for muscle power and strength using the Wingate test and isokinetic dynamometer, respectively. Bioimpedance analysis at 50 kHz was employed to assess WB-PhA and ML-PhA. Lean soft tissue (LST) and fat mass (FM) were quantified using dual x-ray absorptiometry. Performance values were stratified into tertiles for comparisons. Regression and mediation analysis were used to test WB-PhA and ML-PhA as performance predictors.Main results. Women in the second tertile of maximum muscle power demonstrated higher ML-PhA values than those in first tertile (13.6° ± 1.5° versus 11.5° ± 1.5°,p= 0.031). WB-PhA was a predictor of maximum muscle power even after adjusting for LST and FM (ß= 0.40,p= 0.039). ML-PhA alone predicted average muscle power (ß= 0.47,p= 0.008). FM percentage was negatively related to ML-PhA and average muscle power, and it mediated their relationship (b= 0.14; bias-corrected and accelerated 95% confidence interval: 0.007-0.269).Significance. PhA values among tertiles demonstrated no differences and no correlation for strength variables. The results revealed that both WB and ML-PhA may be markers of muscle power in active young women.


Assuntos
Composição Corporal , Músculo Esquelético , Humanos , Feminino , Composição Corporal/fisiologia , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Impedância Elétrica
14.
Neurogastroenterol Motil ; 35(12): e14683, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37793130

RESUMO

BACKGROUND: The Lyon consensus classifies the evidence of gastroesophageal reflux (GERD) based on endoscopic features and results of pH/impedance monitoring (pH-MII) including the post-reflux swallow-induced peristaltic wave index (PSPWI) and mean nocturnal baseline impedance (MNBI). The Wingate consensus established criteria to reduce inter-reviewer variability when assessing reflux episodes and PSPWI by impedance. This study aims to assess the influence of the Wingate criteria on the different pH-MII parameters obtained by automated analysis. METHODS: Thirty consecutive pH-MII off PPI were reviewed according to Wingate criteria. Number of impedance episodes and PSPWI were compared before and after censoring from automatic analysis. Reflux categorization according to Lyon consensus between censored and uncensored data was compared. Pearson correlations between impedance parameters and censored episodes were calculated. KEY RESULTS: Censoring the tracings significantly reduced the number of reflux episodes (66 [42-90.25] vs. 44.5 [21.5-61.5], p = 0.0105). Reasons for censoring were as follows: 1/ anterograde episode: 9.5 [6-13], 2/ impedance drop <50%: 1 [0-3], 3/ duration <4 s: 1 [0-2], 4/ <2 distal channels: 2.5 [1-4], and 5/ artifacts: 2 [1-5]. Censored episodes were in majority non-acid (16.5 [13-26.5] vs. 2 [0-4], p < 0.00001). Censoring altered the categorization of impedance episodes (<40 episodes, 6 vs. 13 for resp. uncensored vs. censored tracings, 40-80 episodes: 13 vs. 13, and >80 episodes: 11 vs. 4, p = 0.0264), but not the symptom index, the symptom association probability, or the categorization according to the Lyon consensus. Nevertheless, individual tracings were affected. The percentage of censored episodes was inversely correlated with the number of acidic impedance episodes (r = -0.62, p = 0.0002). CONCLUSION AND INFERENCES: Manual interpretation of impedance tracings based on the Wingate consensus reduces the number of impedance episodes, impacting on reflux categorization. Acidic reflux episodes are less likely to be censored, harboring a potential at improving automatic pH-MII analysis.


Assuntos
Monitoramento do pH Esofágico , Refluxo Gastroesofágico , Humanos , Monitoramento do pH Esofágico/métodos , Impedância Elétrica , Consenso , Refluxo Gastroesofágico/diagnóstico , Concentração de Íons de Hidrogênio
15.
J Neurogastroenterol Motil ; 29(4): 436-445, 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37814434

RESUMO

Background/Aims: Dilated intercellular spaces (DISs) facilitate the diffusion of noxious agents into the deep layers of the esophageal epithelium. The role of DIS in heartburn pathogenesis is still controversial. Therefore, we aim to reinvestigate DIS in an extensively evaluated group of patients and healthy controls (HCs). Methods: We classified 149 subjects into the following groups: 15 HC, 58 mild erosive reflux disease (ERD), 17 severe ERD, 25 nonerosive reflux disease (NERD), 15 reflux hypersensitivity (RH), and 19 functional heartburn (FH). A total of 100 length measurements were performed for each patient's biopsy. Results: The overall intercellular spaces (ISs) value of gastroesophageal reflux disease (GERD) patients was higher than that of HC (P = 0.020). In phenotypes, mild ERD (vs HC [P = 0.036], NERD [P = 0.004], RH [P = 0.014]) and severe ERD (vs HC [P = 0.002], NERD [P < 0.001], RH [P = 0.001], FH [P = 0.004]) showed significantly higher IS. There was no significant difference between the HC, NERD, RH, and FH groups. The 1.12 µm DIS cutoff value had 63.5% sensitivity and 66.7% specificity in the diagnosis of GERD. There was a weak correlation (r = 0.302) between the IS value and acid exposure time, and a weak correlation (r = -0.359) between the IS value and baseline impedance. A strong correlation was shown between acid exposure time and baseline impedance (r = -0.783). Conclusions: Since the IS length measurement had better discrimination power only in erosive groups, it is not feasible to use in daily routine to discriminate other nonerosive phenotypes and FH. The role of DIS in heartburn in nonerosive patients should be reconsidered.

16.
An. pediatr. (2003. Ed. impr.) ; 99(3)sep. 2023. tab
Artigo em Espanhol | IBECS | ID: ibc-224930

RESUMO

Introducción: La valoración nutricional en anorexia nerviosa (AN) incluye determinar la composición corporal y monitorizar su evolución a lo largo del periodo de tratamiento. La prueba gold standard para el estudio de la composición corporal es la absorciometría de rayos X de energía dual (DEXA), si bien la bioimpedancia eléctrica (BIA) se postula como una alternativa más accesible, barata, rápida y que no irradia. Material y métodos: Se reclutaron secuencialmente a 33 mujeres adolescentes (11,7-16,3 años) diagnosticadas de AN. Se recogieron parámetros clínicos, antropométricos y analíticos, y se realizó BIA y DEXA a la inclusión en el estudio y a la finalización del mismo con separación media de un año, durante la fase de rehabilitación nutricional. Resultados: Se objetivó mejoría significativa a nivel nutricional, reflejada en la composición corporal obtenida mediante antropometría y BIA. El ángulo de fase aumentó significativamente durante el periodo de seguimiento. Una mayor pérdida ponderal se correlacionó con la presencia de amenorrea secundaria y con una menor densidad mineral ósea en columna. Conclusiones: La BIA es una herramienta útil para la valoración y el seguimiento del estado nutricional en pacientes con AN en edad pediátrica. La DEXA sigue siendo imprescindible para conocer la afectación de la densidad mineral ósea. El papel de hormonas como la leptina está aún por determinar. (AU)


Introduction: Nutritional status assessment in anorexia nervosa (AN) includes the evaluation and monitoring of body composition throughout the treatment period. The gold standard for the study of body composition is dual-energy X-ray absorptiometry (DEXA), although electrical bioimpedance (BIA) is a more accessible, cheaper and faster method that does not involve exposure to radiation. Material and methods: We recruited 33 female adolescents with AN (age, 11.7-16.3 years) by consecutive sampling. We collected data on clinical, anthropometric and laboratory variables. Patients were assessed with BIA and DEXA at inclusion in the study and at the end of the study, with a mean duration of followup of 1 year, during the nutritional rehabilitation phase. Results: There was significant improvement in nutritional status, reflected by the body composition obtained by anthropometric measurements and BIA. The phase angle increased significantly during the followup. Greater weight loss was associated with the presence of secondary amenorrhoea and decreased bone mineral density in the spine. Conclusions: Electrical BIA is a useful tool for assessment and monitoring of nutritional status in paediatric patients with AN. Dual-energy X-ray absorptiometry continues to be essential to assess bone mineral density. The role of hormones such as leptin remains to be elucidated. (AU)


Assuntos
Humanos , Feminino , Gravidez , Adolescente , Anorexia Nervosa/diagnóstico por imagem , Anorexia Nervosa/diagnóstico , Composição Corporal , Impedância Elétrica , Densitometria , Estado Nutricional , Estudos Longitudinais , Epidemiologia Descritiva
17.
An Pediatr (Engl Ed) ; 99(3): 162-169, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37563070

RESUMO

INTRODUCTION: Nutritional status assessment in anorexia nervosa (AN) includes the evaluation and monitoring of body composition throughout the treatment period. The gold standard for the study of body composition is dual-energy X-ray absorptiometry (DEXA), although electrical bioimpedance (BIA) is a more accessible, cheaper and faster method that does not involve exposure to radiation. MATERIAL AND METHODS: We recruited 33 female adolescents with AN (age, 11.7-16.3 years) by consecutive sampling. We collected data on clinical, anthropometric and laboratory variables. Patients were assessed with BIA and DEXA at inclusion in the study and at the end of the study, with a mean duration of follow-up of 1 year, during the nutritional rehabilitation phase. RESULTS: There was significant improvement in nutritional status, reflected by the body composition obtained by anthropometric measurements and BIA. The phase angle increased significantly during the follow-up. Greater weight loss was associated with the presence of secondary amenorrhoea and decreased bone mineral density in the spine. CONCLUSIONS: Electrical BIA is a useful tool for assessment and monitoring of nutritional status in paediatric patients with AN. Dual-energy X-ray absorptiometry continues to be essential to assess bone mineral density. The role of hormones such as leptin remains to be elucidated.


Assuntos
Anorexia Nervosa , Estado Nutricional , Humanos , Feminino , Adolescente , Criança , Índice de Massa Corporal , Anorexia Nervosa/terapia , Anorexia Nervosa/complicações , Composição Corporal , Densidade Óssea
18.
Methods Mol Biol ; 2644: 81-97, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37142917

RESUMO

Single-cell impedance measurement is label free and noninvasive in characterizing the electrical properties of single cells. At present, though widely used for impedance measurement, electrical impedance flow cytometry (IFC) and electrical impedance spectroscopy (EIS) are used alone for most microfluidic chips. Here, we describe high-efficiency single-cell electrical impedance spectroscopy, which combines in one chip the IFC and EIS techniques for high-efficiency single-cell electrical property measurement. We envision that the strategy of combining IFC and EIS provides a new thought in the efforts to enhance the efficiency of electrical property measurement for single cells.


Assuntos
Espectroscopia Dielétrica , Análise de Célula Única , Análise de Célula Única/métodos , Microfluídica/métodos , Impedância Elétrica , Citometria de Fluxo/métodos
19.
Foods ; 12(9)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37174377

RESUMO

Vegetable oils provide lipids and nutrition and provide foods with a desirable flavor, color, and crispy texture when used to prepare fried foods. However, the oil quality is degraded at elevated temperatures, and thus must be examined frequently because of the damage to human health. In this study, sunflower, soybean, olive, and canola oils were examined, and their properties were measured periodically at different elevated temperatures. The unsaturated triglyceride in oils reacted with the environmental oxygen or water vapor significantly changes in optical absorbance, viscosity, electrical impedance, and acid value. We used defect kinetics to analyze the evolution of these oil properties at elevated temperatures. The optical absorbance, viscosity, and electrical impedance follow the second-order, first-order, and zeroth-order kinetics, respectively. The rate constants of the above kinetics satisfy the Arrhenius equation. Olive oil has the lowest rate of color center and dynamic viscosity among the four oils, with the smallest pre-exponential factor and the largest activation energy, respectively. The rate constants of acid reaction also satisfy the Arrhenius equation. The activation energies of the polar compound and acid reaction are almost the same, respectively, implying that the rate constant is controlled by a pre-exponential factor if four oils are compared. Olive oil has the largest rate constant of acid reaction among the four oils, with the lowest pre-exponential factor.

20.
Circ Heart Fail ; 16(5): e010012, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37192288

RESUMO

BACKGROUND: There is a need for simple, noninvasive solutions to remotely monitor and predict worsening heart failure (HF) events. SCALE-HF 1 (Surveillance and Alert-Based Multiparameter Monitoring to Reduce Worsening Heart Failure Events) is a prospective, multicenter study that will develop and assess the accuracy of the heart function index-a composite algorithm of noninvasive hemodynamic biomarkers from a cardiac scale-in predicting worsening HF events. METHODS: Approximately 300 patients with chronic HF and recent decompensation will be enrolled in this observational study for model development. Patients will be encouraged to take daily cardiac scale measurements. RESULTS: Approximately 50 HF events, defined as an urgent, unscheduled clinic, emergency department, or hospitalization for worsening HF will be used for model development. The composite index will be developed from hemodynamic biomarkers derived from ECG, ballistocardiogram, and impedance plethysmogram signals measured from the cardiac scale. Biomarkers of interest include weight, peripheral impedance, pulse rate and variability, and estimates of stroke volume, cardiac output, and blood pressure captured through the cardiac scale. The sensitivity, unexplained alert rate, and alerting time of the index in predicting worsening HF events will be evaluated and compared with the performance of simple weight-based rule-of-thumb algorithms (eg, weight increase of 3 lbs in 1 day or 5 lbs in 7 days) that are often used in practice. CONCLUSIONS: SCALE-HF 1 is the first study to develop and evaluate the performance of a composite index derived from noninvasive hemodynamic biomarkers measured from a cardiac scale in predicting worsening HF events. Subsequent studies will validate the heart function index and assess its ability to improve patient outcomes. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04882449.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/diagnóstico , Estudos Prospectivos , Hospitalização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...